BOILERS

Stationary boilers – water-tube, membrane

  • Gas type, with maximum output of 150 tonnes/h, or with maximum pressure of 9.6 MPa, depending on the customer’s requirements
  • Oil type, with maximum output of 150 tonnes/h, or with maximum pressure of 9.6 MPa, depending on the customer’s requirements
  • Powder type, with output of 35–150 tonnes/h, or with maximum pressure of 9.6 MPa, depending on the customer’s requirements
  • Fluidized bed boilers, with output of 45–115 tonnes/h for the combustion of bituminous coal with a high heat content
  • Grate type, with steam output of 4–240 tonnes/h, hot-water design, 2.8–36 MW
  • Boilers burning wood, agricultural and other waste, or combinations of waste and coal

Boilers for waste heat utilization

  • For heat recovery from combustion turbines
  • For the use of exhaust gases from municipal and industrial waste incineration plants
  • For heat recovery from the exhaust gases of glass furnaces
  • Additional surfaces for boilers – water or air heaters

Portable boilers of the KTK type

Portable boilers of the KTK type are manufactured in both steam and hot-water designs for the combustion of gaseous and liquid fuels. They are water-tube, mono-drum boilers with natural circulation and a membrane design, assembled in the manufacturing plant. The boilers are supplied with a tube water heater and a tube air heater, reaching efficiency rates of up to 95%.

Output range of the steam design: 8–25 tonnes/h, steam pressure: 0.9–1.4 MPa, steam temperature: 200–250 °C.

Output range of the hot-water design: 5–25 MW, pressure: 2.4 MPa, water temperature: 150/70 °C.

Portable boilers of the OKP type

Portable boilers of the OKP type are manufactured in both steam and hot-water designs for the combustion of gaseous and liquid fuels. They are water-tube, bi-drum boilers with natural circulation and a membrane design, assembled in the manufacturing plant. The boilers feature economizers to achieve high efficiency rates.

Output range of the steam design: 8–40 tonnes/h., steam pressure: 1.4; 2.5; 3.8 MPa, steam temperature: 220; 380; 445 °C (the parameters can be further customized).

Output range of the hot-water design: 5.6–17.5 MW, pressure: 1.4; 2.5; 3.8 MPa, water temperature: 150/70 °C (the parameters can be further customized).

Boiler packages for industrial heat-only boiler stations

Fire-tube boilers are manufactured in both steam and hot-water designs for the combustion of gaseous and liquid fuels as large-volume units with natural circulation and high pressure combustion. The boilers are completely assembled including all accessories in the manufacturing plant. They are designed for unattended operation.

Output range 1–14 tonnes/h, saturated or superheated steam: 220 °C (can be optionally increased to 300 °C), 1.4 MPa (can be optionally increased to 2 MPa), hot water: 150/70 °C.

BOILER ACCESSORIES

Accessories for solid-fuel boilers

  • belt, screw or impeller feeders
  • cooled screw feeders for hot ash and fly ash
  • multi-shaft feeders
  • redler chain feeders and conveyors
  • cooled Redler chain and screw conveyors
  • belt and screw conveyors and their accessories
  • steel silos with arch breakingb
  • hand-operated and mechanical closures
  • pressure caps
  • wet bottom ash extractors of various designs – raking, plate and shovel type
  • hammer mills with separators for milling lignite
  • moistening screws
  • apron conveyors
  • low-speed bucket elevator for ash materials

Piping

All connecting pipes for water, steam, liquid fuels and gas, including manifolds, expansion joints, supporting structures, suspension material etc.

Supporting structures

Steel supporting structures, building structures, platforms, footbridges, stairs and ladders.

WATER TREATMENT EQUIPMENT

Water treatment equipment

  • Clarifiers
  • Lamella separators
  • Ion-exchange filters
  • Countercurrent ion-exchange filters
  • Double-chamber countercurrent ion-exchange filters
  • Straining parts for ion-exchange filters
  • Fine filters 
  • Sand filters 
  • Mixed bed filters
  • Universal softening filters
  • Deaerator nozzles
  • Deaerators
  • Flocculation chambers
  • Steam and hot water coolers
  • Injectors for regeneration solutions
  • Injectors for bulk materials

Pressure tanks

  • Air chambers
  • Air tanks
  • Expanders
  • Releasers
  • Other low-pressure and high-pressure heaters

Tanks

Non-pressure vertical storage vessels

Heat exchangers

Horizontal capillary exchangers for indirect heat exchange in the heating equipment of water treatment plants, in hot-water heating stations for the heating or cooling of water, condensates, etc.